遵循这些指导方针可以为您的企业节省资金和能源.
空气需求量变化较大的电厂需要一个在部分负荷下高效运行的系统. 在这种情况下, 多台具有顺序控制的压缩机可提供更经济的操作选择. 负荷曲线更一致的电厂能够使用更简单的控制策略.
Replacing light switches with occupancy sensors in walk-in refrigerators and freezers can save nearly $200 a year in 能源 costs and reduce the load on the compressor.
不要把闪光的蒸汽排到大气中去浪费它. 各种工业都使用高、中压蒸汽,其中含有可回收的有价值的能量. 用这些蒸汽预热生活热水或从大楼供暖系统返回的热水.
Utilizing high-efficiency compressor systems can result in significant 能源 savings–roughly 6 percent for ice machines and as much as 16 percent for reach-in freezers.
根据 艾默生网络能源, properly designed supplemental cooling has been shown to reduce data center cooling 能源 costs by 35 to 50 percent compared to perimeter cooling only.
检查密封出口和间隙之间的造型,以及管道和电线的渗透. 其他的检查点包括舱口、管道通风口、烟囱和其他穿透屋顶或墙壁的地方. Many areas can be sealed by caulking. Use foam sealants for larger areas.
Aluminum 窗户 should have an insulating section — a thermal break — between the inner and outer aluminum sections of the frames. 这一基本特性将金属的热导率降低到与木材相同的水平.
能源审计可以帮助您了解您的设施如何使用各种形式的能源-包括电力, 气体, 和其他公用事业,并帮助你识别浪费或效率低下. By identifying on-peak and off-peak periods, 您可以使用来自审计的信息来利用各种费率结构.
当建造一座新建筑或更换旧系统时, 考虑安装变速驱动冷水机组和/或地热热泵. 它们的运作效率比行业平均水平高出30%. 地热泵的安装成本可能比传统的暖通空调设备更高, 但它们的操作成本比传统的暖通空调系统低.
增加天窗可以采光,从而减少能源消耗. 研究表明,白昼时间的增加也能提高员工的工作效率.
使工作的大小与设备的大小相匹配. Combi-ovens, turbo-ovens, 无连接蒸笼可以加快烹饪时间,节约水和能源. 当使用电动灶台时,要将平底锅的大小与灶具的大小相匹配. 在8英寸的燃烧器上放置6英寸的平底锅会浪费掉40%的热量.
在晚上,在餐厅使用烛光. 使用烛光不仅增加了餐厅的气氛, 但它也为你的餐厅或餐饮服务机构节省了能源成本. 在适当的时候使用.
在实际情况下,回收和再利用空调和制冷设备的余热. 余热捕获设备包括热气体减温器, 双束冷凝器和辅助冷凝器.
在运行数小时后,通过设施来识别能源浪费, 检查设备设置, 建立一个能源关闭/关闭程序的清单,并与工厂经理和员工一起审查你的发现. Continue to inspect the plant, 确保遵守节能程序的系统和设备.
如果你的酒店员工能够分批预订房间, 您将提高您的设施的效率,而不影响热情好客的体验.
大多数电机的运转速度是其配套铭牌上显示的马力的75%. 在驱动负载下,一个超大的电机通常比一个较小的电机效率更高.
根据 艾默生网络能源,任何数据中心的首要任务都是使用精密冷却. Second is to optimize air flow. 您可以通过将机架安排在热通道/冷通道配置中来做到这一点, 通过减少空气再循环和使用管道将热空气返回到冷却装置. 持续监控您的系统并进行热评估,以确保您保持在正轨上.
Create a document that employees or occupants can reference for compliance and guidance around your organization’s 能源 management policy. 根据需要更新文件,以反映节能成果和新的政策或程序.
Installing electric radiant heaters in areas frequented by employees or workers will keep occupants warm without excessive heat loss. Adding a timer or occupancy sensor to the heater will keep even a small area from being heated if there’s no one in it.
在厨房里,规范通常要求更高的水温. 然而, 将厨房区域外的水温设置为120°F将有助于减少能源消耗和控制费用.
为了减少高能量使用期间的能源需求,可以考虑负荷转移. Using a thermal 能源 storage system, 在低能使用期间获取非高峰电能,并在以后使用, during periods of high 能源 demand.
Reducing pumping power in cooling systems can be accomplished by eliminating bypass valves and three-way valves; removing auto flow valves, 压力调节阀及其他限流器, and opening balancing valves at the pump.
通过增加景观美化来减少建筑周围的铺装量. 这将有助于建筑物在夏天保持凉爽.
Using variable speeds on pumps, 在不同负荷下运行的风扇和压缩机将降低高峰和非高峰的能源成本.
发动机发热是老化或不健康的标志. 它还表示低效率和/或低于平均性能. 为了评估电机的真正效率,测量电机的实际输出与电流.
If your water pressure exceeds 40 to 50 psi, 安装减压阀,降低能源成本. 如果压力表显示水压过高, 考虑让管道工在主要设备上安装减压阀. 这个阀门将限制从水龙头流出的热水的数量,并降低能源成本.
能源-saving TLEDs make sense in larger, 占用空间, 但它们的输出在壁橱和走廊里是不必要的. 使用能源之星认证的LED灯泡,既省钱又节能. Also consider installing dimmers and/or timers that would reduce hallway light levels by up to 30% during daylight hours.
在建筑物内重复利用热能的机会很多. 例如, 空调或制冷设备产生的废热通常可用于满足建筑需求. 收集废热, 热气体减温器, 双束冷凝器和辅助冷凝器 can be used on almost every type of air conditioning and refrigeration equipment.
Vending machine controls can be used to cycle refrigeration compressors on and off based on a predetermined temperature range. 在数小时后或某一空间未被占用时, 自动售货机控制可以关闭自动售货机照明, and turn it back on when motion is detected. If automatic controls are not an option, 减少或移除机器上不必要的灯泡.
取代你的10, or 20 watt incandescent lamps in your facility’s exit signs with Light Emitting Diode (LED)-powered signs leads to savings. led更容易维护, 持续时间更长, 而且比白炽灯和霓虹灯便宜. “能源之星”估计,一个led照明的出口标识每年比一个白炽灯标识少花费50美元.
采用高效冷凝器风扇电机,可节省3%至5%的能源成本.
To improve motor reliability and efficiency, www.能源.政府 建议您保持正确的电压和相位平衡, identify and eliminate current leaks, and prevent harmonics in the electrical supply. 能源部还建议让电气工程师审查电气系统. 在安装新电机之前或在对系统或系统负载进行更改之后进行检查.
适合办公室, 教室, and meeting or conference rooms, bi-level switching allows occupants to turn on a group of fixtures–such as half the lights or a third of the lights–when using all the lights is unnecessary. 与管家或保管员一起工作,确保没有不必要的灯亮着. 制定一个非正式的甚至正式的监控计划, 其中包括对下班后关灯的激励或奖励. 考虑将合规作为内务管理、承建商或员工表现衡量标准的一部分.
一个典型的餐厅或食品服务设施将节省高达15美元,通过为其厨房配备节能或ENERGY STAR®合格设备,每年可获得5000万美元.
同时还能节省高达50%的能源成本, 多层展示柜上的玻璃门可以减少冷空气的溢出, 防止压缩机加班,增加客户舒适度.
In facilities such as congregations and schools, 记录会议空间和教室的使用情况. Using appropriately sized meeting spaces for the number of occupants gathered will save you money on heating and/or cooling and lighting. Tracking meeting room usage will help you recognize patterns and help you identify how best to schedule gatherings and increase 能源 efficiency.
每3-6个月校准气动恒温器,避免效率下降.
根据 Liebert 服务 failure tracking, 超过三分之一的不间断电源(UPS)系统故障是由电池相关故障引起的. Monitor and maintain your UPS and its batteries either via manual tests or via remote monitoring and management software.
使用电动叉车不仅能减少排放,还能让您的作业更环保, but it will also save you money on ventilation.
考虑用一个变频驱动器控制所有冷却塔风扇,并一起调节风扇转速.
In areas with a moderate to warm climate, 热泵系统可以做一个标准的电热水器的工作,而使用一半的电力. 热泵也会将设备内部的热量转移到水箱中, reducing the load on your HVAC system.
建筑物外部(如墙壁)看似很小的裂缝或洞, 窗户, 门, 天花板和地板)会造成大量的供热或制冷损失. 安装防风雨条和嵌缝以修补漏气处.
不要忽视暖通机械系统的微小改进. 这些包括安装烟道阻尼器或平衡通风系统,以减少排气率, 重新安装恒温器,安装风扇,防止热空气进入天花板, and installing thermostats in hot water tanks.
为确保热水器正常工作,应定期检查泳池水温. 水温过高可能表明热水器使水过热. 国家游泳池基金会建议泳池温度设置在78到84华氏度之间, depending on the pool’s usage. 覆盖一个加热的游泳池可以节省50% - 70%的能源消耗. 它还可以减少水的流失,防止用于处理水的化学物质的流失35- 60%.
在有多个冷却塔和冷却器的工厂里, 通过使所有的水在塔上而不是仅仅在一个塔上运行来促进热传递.
使用占用传感器来自动开启和关闭低交通空间的灯, 包括卫生间, 休息的房间, supply rooms and locker rooms.
One of the most cost-effective conservation measures available is to add roof insulation–including a vapor barrier–when you’re replacing a roof. 对于历史建筑或新建筑来说,增加绝缘材料的成本会带来快速的回报.
如果你的照明系统使用能量磁镇流器和“瓦特吝啬鬼”灯, 您可以升级到一个标题系统,以进一步节省.
使用蒸汽涡轮机捕获减压阀的能量损失. PRV可以通过背压涡轮机绕过,它排出的蒸汽压力与PRV相同. 例如,涡轮机可以用来驱动发电机、泵、冷水机或压缩机. 一台背压式涡轮机,供压250磅,排气15磅, 扩大20,每小时000英制热量单位蒸汽, 能驱动一个高达129千瓦的发电机吗. If this turbine operates for 6,每年000小时, 所产生的电力价值可能高达40美元,000.
无论何时使用中高压蒸汽锅炉, 冷凝系统中会有闪蒸. 这种闪光蒸汽含有可回收的宝贵能量. 高、中压蒸汽用于多种结构中, 包括医院, universities and industrial facilities. Good uses for the recovered heat are to preheat domestic hot water or to preheat returned hot water from the building’s heating system. 大约5%到15%的冷凝液会在大约5psi的压力下闪蒸. 如果这些蒸汽被排放到大气中,热量就被浪费了.
在浴室安装动作激活的夜灯,因为顾客经常让浴室的灯开着. 通过提供运动激活灯,你可以减少对全光照明的需求.
Every NEMA standard polyphase Design B motor below 150 hp (and many well above that) has an efficiency value stamped on its nameplate. 该值是代表该特定设计的“名义”值. 对于每一个这样的值,一个“最小值”,或保证值,在NEMA标准中公布. 因此,在比较品牌时,最好以NEMA的评级为指导. While some motor lines may offer efficiencies far above the NEMA “能源 efficient” value; some “standard” motor lines may also reach high levels for some ratings. 让你具体的经济分析为你指出最佳的解决方案.
定期清洁和维护暖通机械系统,以最大限度地提高效率. 检查是否有脏线圈和限制空气流动的过滤器, 宽松的风扇皮带, 外部空气阻尼器不能正确关闭和控制阀功能不正常.
大多数锅炉燃烧时使用的空气过多,从而浪费能源. 氧气微调器可调节供给燃烧器的空气量,提高效率. 例如, the installation of an O2 trim system would result in an increase in efficiency of 1 to 2 percent for a 250 hp boiler running 2,每年000小时. 这相当于节省了大约1700美元的能源成本. 这种体积的组合式锅炉每台的初始费用约为9 000美元. 如果锅炉每年运行超过2000小时,节省的费用就会相应更高.
利用高峰期的价格,在非高峰期提供洗衣服务. 这也将有助于减少设备系统的负载.
电机管理有助于减少停机时间,降低能源成本,提高生产力. The keys to good motor management:
以下步骤将帮助您了解您的真实成本, 在电机故障的情况下提前计划,确保您有正确的电机,当您需要它的时候.
配备最先进的灯具或镇流器(T8灯具,电子镇流器等).)通常需要较高的补强时间或补强压载时间. Much of this cost is offset by their longer life, 降低了更换部件的成本,降低了维护成本.
Monitoring a chiller’s kW/ton performance offers additional optimization opportunities and is often achieved for little additional cost. 根据劳伦斯伯克利国家实验室的研究, 真功率kW传感器, 这包含了电压, amperage and power factor measurements, should be selected to monitor chiller power. 用于整个工厂的监测, 变频驱动通常提供了一种经济的方式来监测较小的功耗, lower-priority loads such as pumps and towers.
记住,从生命周期的角度来看,系统中最便宜的部分是灯具和灯具. 最昂贵的部分是系统使用的能源.
Ozone laundering systems use cold water (vs. 热水),以及比传统洗衣系统更少的水、能源和洗涤剂. 臭氧洗衣系统预计寿命为20年,具体寿命取决于您设备的大小和体积, can reach payback in 1 to 2 years.
蒸汽疏水阀是一种自动阀门,可以从锅炉中释放冷凝蒸汽,防止活蒸汽流失. 它们通常会卡在打开的位置,导致大量多余的能源消耗. 超声波检漏仪用于检测有故障的陷阱. By isolating sound frequencies, 这些工具将检测到的频率与正常工作的陷阱进行比较, and offer users an analysis via digital display.
即使分析表明锅炉是高效运行的, 在夏季,锅炉往往过大,利用率不高. 您的设备可能需要考虑用小型热水器来增强其水加热系统, 适当大小的锅炉,以减少负荷条件.
To provide comfort and 能源 efficiency, be sure to adequately insulate walls, 屋顶, and floors according to your climate zone. 这样做将提供乘员舒适和提高能源效率. Pay special attention to the roof. 屋顶在夏季容易受到太阳热量的吸收,而在冬季容易受到热量的损失.
在1960年以前建造的建筑中,不保温的砖墙很常见. 你可以用三种常用方法中的一种来隔离它们, insulating the cavity or insulating the exterior. 毛皮是最简单和最便宜的,并提供了一个完整的墙壁表面. 它通常包括用螺柱或滑轨来构造内部, 在管道之间放置绝缘材料,并完成墙面.
不要让冰箱过度工作,把它们放在靠近暖气口、厨房灶具或洗碗机的地方.
单人用餐, 大板, restaurants and food service operations can save 能源 costs by reducing the number of plates and dishes that need to be washed.
检查建筑围护结构组件应该是设施整体操作和维护计划的一部分. Your plan should include a visual survey, repairs of any detected deterioration (such as cracks in 屋顶 and walls insulation) and inspecting 窗户 for leaks.
来计算数据系统的电力需求, 您需要有关冷却系统所需功率的数据, the uninterruptible power supply (UPS) system, and the IT loads of the center. 根据 Cisco Systems, Inc., 而这些元件的功率要求可能会有所不同, 一旦确定了预计IT负荷的电力需求,就可以准确地估计它们. 此计算也可用于估计备用发电机所需的功率输出能力.
水环热泵系统的应用包括学校, 医疗中心, 酒店, offices and even small airports. 从核心区域和同时供热/制冷的情况下有能源回收的机会. 回收的能量可以重新分配到空间调节和生活用水加热. Costs are typically low for installing, operating and maintaining these systems, and they are adaptable to future 能源 sources, 比如太阳能加热.
Pipe insulation will keep cold water pipes from sweating (water vapor condensing on the pipe surface) in warm weather and reduce heat loss from hot water pipes. 众所周知,水分会导致各种类型的腐蚀, 因此防止冷凝在管道上形成是非常重要的. 绝缘 will also help keep those water pipes located outside from freezing when the ambient temperature drops below freezing. When specifying piping insulation, 注意最高和最低温度,管道将暴露和绝缘两者.
Well-functioning strip and/or swinging plastic door curtains are a low-cost way to keep cold air from escaping from walk-in coolers. 这减少了冷冻压缩机的运行时间,节省能源,延长了压缩机的寿命. 条状窗帘还可以防止温暖、潮湿的空气进入冰箱.
Preheating is a common and costly practice. 大多数烹饪设备的预热时间都很短——通常是10到15分钟——有些设备也是如此, such as griddles and broilers, require little or no preheating time. 调查所有设备的确切预热时间, and post the preheat times near the equipment. Train employees to preheat accordingly.
为了节约能源,允许电梯“暂停”并慢慢关闭. 它们应该闲置足够长的时间,使功耗等于, 或者几乎少于, 起动电机时所消耗的功率.
If you work with a vending machine company, 它应该能够帮助您评估当前自动售货机的可能升级. ENERGY STAR®合格自动贩卖机使用的能源约减少40%,并保持饮料作为标准机器.
电, 辐射加热器的效率几乎是百分之百, 与气体加热器, 不排放二氧化碳, nitrous oxide or other toxins. Based on the same principle as the sun, 辐射式加热器加热的是其范围内的物体,而不是加热器和物体之间的空气. 利用辐射热能, 这些加热器会瞬间加热光束内的人和物体. 因此,它们在风中也能很好地工作.
通过降低你的建筑物加热设定点70度,当有人居住和62度,无人, 你可以省下超过25美元,年薪为240,000平方英尺的建筑, 根据 www.ecova.com.
一个蓄热槽可以让你在非高峰期运行冷水机设备,并储存冷却水或冰, then draw on this cooling during peak times.
冷水机的性能受其有效传热能力的影响. If the evaporator and condenser tubes are dirty, it will decrease a chiller’s ability to transfer heat and subsequently increase the compressor’s 能源 consumption by 30 percent or more.
Clean heat exchangers and perform routine maintenance on refrigerating equipment to ensure efficient operation and to reduce 能源 costs.
The installation of an economizer, 一种预热给水(返回的冷凝水)的装置, 能使锅炉的效率提高2 - 3%吗. 为了提高效率,维修或更换损坏或丢失的锅炉绝缘材料.
根据 Alliance for 水 Efficiency, depending on the level of treatment necessary, 温水回收设备可以回收10- 90%的灰色或洗涤水(从淋浴中流出), 洗澡, and laundry) while conserving 能源.
充分利用Georgia Power的专家建议和服务. 我们提供技术能源审计,回报计算,成本比较和费率分析.
为了降低能源成本,在可行的时候关闭制冰机. 此外,一定要定期清洗制冰机的冷却装置. 为了帮助降低维护成本,可以考虑具有自清洁功能的机型.
The further south your facility is located, 而且玻璃占空间的比例越高, 更重要的是阻挡太阳能,避免热量增加. 在有大面积朝南玻璃的建筑物里, 热量的增加会给保持舒适带来严重的问题. 窗户着色或反射涂层可以反射多达90%的太阳热量. 除了最北部的气候,它们可以为所有地区提供储蓄, 在哪里获得热量是可取的, helping to reduce winter heat load significantly. 一般来说,超过25%的玻璃幕墙空间的建筑可以受益于太阳能控制玻璃.
利用干燥器中的空气对空气热交换器, 热回收系统利用余热,让进来的空气被干燥机的排气加热. 它们可以将烘干机所需的能量减少50%.
In summer, ceiling fans help cool a space. 在寒冷的几个月, 倒转风机方向,利用吊扇将聚集在吊顶区域的热空气循环. 流动的空气比不流动的空气感觉凉爽3到5度,可以节省3%的冷却成本.
作为一个群体,学生是学校或校园里最大的能源消耗者之一. 利用推广、教育和激励计划让他们参与到节能活动中来.
为了提高效率,维修或更换损坏或缺失的锅炉绝缘材料.
电子空气清洁器具有低、恒定的空气阻力. 这种低静压有助于降低能源成本. 一个标准过滤器的空气阻力增加,因为它变得脏-增加风扇静压, and causing the motor to work harder. 考虑在建筑空气处理单元安装它们,而不是标准的坏过滤器或过滤器.
在任何现场设施安装低流量水龙头和洗碗设备. 节水淋浴喷头每分钟可以产生3到4加仑的淋浴体验, 但每分钟消耗的水量远远少于2加仑. You should also repair any water leaks promptly.